Fermacell ceilings with steel and timber substructures

  Ceiling Weight Construction Height Fire Rating
System Specifications kg/m 2 mm mins
2S11↑U
2s11u Channels 60mm x 0.6 @ max 400mm centres 27 75 30
Facings 2 layers 10mm Fermacell Board one side
Type Suspended steel ceiling system with fire protection from below. Min 0.6 gauge. Confirm hanging and layout first
Channels 60mm x 0.6 @ max 500mm centres 33 80 30
Facings 2 layers 12.5mm Fermacell Board one side
Insulation None
Type Suspended steel ceiling system with fire protection from below. Min 0.6 gauge. Confirm hanging and layout first
2S01 H20
2s01-h20

Download

Channels 60mm x 0.6 @ max 500mm centres 16 70 N/A
Facings 1 layer 12.5mm Powerpanel H2O one side
Insulation None
Type Suspended steel ceiling system with fire protection from below. Min 0.6 gauge. Confirm hanging and layout first
2S11 H20↑U
2s11-h20

Download

Channels 60mm x 0.6 @ max 500mm centres 32 80 30
Facings 1 layer 12.5 mm Fermacell Board plus 1 layer 12.5 mm Powerpanel H2O one side
Insulation None
Type Suspended steel ceiling system with fire protection from below. Min 0.6 gauge. Confirm hanging and layout first

Fermacell timber ceilings

  Ceiling Weight Sound Insulation Fire Rating from below
System Specifications kg/m 2 Rw mins
2H12
2h12

Battens optional when joist centres exceeds 400mm

Download

Battens Timber battens min 48mm x 24mm, steel resilient bar or MF suspended ceiling at max 400mm centres 16 >40 30
Facings 1 layer 10mm Fermacell Board one side
Insulation Optional - required for acoustic performance
Type Timber joisted ceiling systems with a layer of structural overlay board
Battens Timber battens min 48mm x 24mm, steel resilient bar or MF suspended ceiling at max 500mm centres 19 40 30
Facings 1 layer 12.5mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems with a layer of structural overlay board
2H15
2h15

Download

Battens Engineered timber joists min 235mm deep/without timber battens minimum 50mm x 30mm at max 400mm centres 35 Part E min. 40 dB N/A
Facings 1 layer 12.5mm or 1 x 15mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems with a layer of structural overlay board
2H21
2h21 Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 425 mm centres 35 Part E min. 40 dB 60
Facings 2 layers 12.5 mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems with a layer of structural overlay board
2H23
2h23

Download

Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 400 mm centres 29 45 60
Facings 2 layers 10mm Fermacell Board one side
Insulation 50mm mineral stone wool density 60kg/m3 or 100mm mineral stone wool density 30kg/m3
Type Timber joisted ceiling systems with a layer of structural overlay board
Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 400 mm centres 35 50 60
Facings 2 layers 12.5mm Fermacell Board one side
Insulation 50 mm mineral stone wool density 60 kg/m3 or 100 mm mineral stone wool density 30 kg/m3
Type Timber joisted ceiling systems with a layer of structural overlay board
2H31
2h31

Download

Battens Timber joists with 2 sets of battens min 60 mm x 40 mm, or for lower batten steel resilient bar or MF suspended Ceiling at max 350 mm centres 38 N/A 90
Facings 2 layers 10mm Fermacell Board one side
Insulation 50mm mineral stone wool density 80kg/m3 with wire netting to hold up insulation
Type Timber joisted ceiling systems with a layer of structural overlay board
Battens Timber joists with 2 sets of battens min 60 mm x 40 mm, or for lower batten steel resilient bar or MF suspended Ceiling at max 350 mm centres 44 N/A 90
Facings 2 layers 12.5mm Fermacell Board one side
Insulation 50 mm mineral stone wool density 80 kg/m3 with wire netting to hold up insulation
Type Timber joisted ceiling systems with a layer of structural overlay board

Fermacell timber roof constructions

  Ceiling Weight Construction Height Fire Rating from below
System Specifications kg/m 2 mm mins
2HD11
2hd11

* Roofing batterns

Download

Battens Timber battens min 50 mm x 30 mm, steel resilient bar or MF suspended ceiling at max 400 mm centres 17 40 30
Facings 1 layer 10mm Fermacell Board one side
Insulation 100 mm mineral stone wool density 15 kg/m3
Type Timber joisted ceiling systems without a layer of structural overlay board
Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 500 mm centres 20 45 30
Facings 1 layer 12.5 mm Fermacell Board one side
Insulation 100 mm mineral stone wool density 15 kg/m3
Type Timber joisted ceiling systems without a layer of structural overlay board
2HD12
2hd12

* Roofing batterns

Download

Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 400 mm centres 29 45 30
Facings 2 layer 10mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems without a layer of structural overlay board
Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 500 mm centres 16 35 30
Facings 2 layer 12.5 mm Fermacell Board one side
Insulation None required
Type Timber joisted ceiling systems without a layer of structural overlay board
2HD13
2hd13

Download

Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 400 mm centres 16 35 30
Facings 1 layer 10mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems with a layer of structural overlay board
Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 500 mm centres 19 40 30
Facings 1 layer 12.5 mm Fermacell Board one side
Insulation None required
Type Timber joisted ceiling systems with a layer of structural overlay board
2HD21
2hd21

Download

Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 400 mm centres 29 45 60
Facings 2 layer 10mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems with a layer of structural overlay board
Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 500 mm centres 35 50 60
Facings 2 layer 12.5 mm Fermacell Board one side
Insulation Optional
Type Timber joisted ceiling systems with a layer of structural overlay board
2HD34
2hd34

* Roofing batterns

Download

Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 500 mm centres 54 ≥65 90
Facings 1 layer 15 mm Fermacell Board plus 2 layers 12.5 mm Fermacell Board one side
Insulation None
Type Timber joisted ceiling systems without a layer of structural overlay board
Battens Timber battens min 48 mm x 24 mm, steel resilient bar or MF suspended ceiling at max 3500 mm centres 54 ≥65 90
Facings 4 layers 10 mm Fermacell Board one side
Insulation None
Type Timber joisted ceiling systems without a layer of structural overlay board

Fermacell flooring

  Element Weight Admissable Point Loading Thickness Fire Rating from below Thermal Performance
System Specifications kN/m2 kN mm mins [1/Δ]m2K/W
2E11
2e11 Type 20mm dry flooring element 0.23 2* 20 30 0.06
Areas of Application 1 + 2
2E22
2e22 Type 25mm dry flooring element 0.29 3* 25 60 0.075
Areas of Application 1 + 2 + 3
2E13
2e13 Type 20 mm dry flooring element + 20 mm rigid foamed polystyrene 0.23 2 40 30 0.56
Areas of Application 1 + 2
2E14
2e14 Type 20 mm dry flooring element + 30 mm rigid foamed polystyrene 0.23 2 50 30 0.81
Areas of Application 1 + 2
2E31
2e31 Type 20 mm element dry flooring elements + 10 mm wood fibre insulating slab 0.23 2 50 30 0.81
Areas of Application 1 + 2 + 3
OPTION
Type Include 35mm element - using 25mm dry flooring 2 layers 12.5mm Fermacell Board 0.25 1 35 90 0.26
Areas of Application 1 + 2 + 3
2E32
2e31 Type 20 mm dry flooring element + 10 mm mineral wool insulating slab 0.25 1 30 90 0.81
Areas of Application 1
OPTION
Type Include 35 mm dry flooring element + 2 layers 12.5 mm Fermacell Board 0.25 1 35 90 0.31
Areas of Application 1

Where the flooring elements are laid directly onto a concrete or stable base, then the point loading increases as follows:

  • 2E11 - 3.0kN
  • 2E22 - 4.0kN

Fermacell powerpanel flooring

  Element Weight Admissible Point Loading Thickness Fire Rating from below Thermal Performance
System Specifications kN/m2 kN mm mins [1/Δ]m2K/W
H20 TE Flooring
H20-te Type 25 mm Powerpanel dry flooring element for wet areas 0.25 3 25 90 0.15
Areas of Application 1 + 2 + 3

Ranges of use and application

1 Premises and corridors in buildings for habitation, hotel bedrooms with bathrooms.
2 Offices and corridors, surgeries including wards and waiting rooms and corridors ≤ 50 m2 adjacent to an apartment, office or similar buildings.
3 Corridors in hotels, retirement homes and boarding schools or similar buildings. Treatment and operating rooms not containing any heavy equipment.
3 Areas containing tables such as classrooms, cafés, restaurants, dining rooms, lecture halls and reception lounges.
4 Corridors in hospital buildings, retirement homes, treatment rooms and operating rooms containing heavy equipment.
4 Areas intended for large gatherings of people, for example: classrooms, auditoria, churches, theatres, cinemas, conference rooms, waiting rooms, concert halls.
4 Large open areas, for example: museums, exhibition halls, entrances to public buildings and hotels.
4 Sports and leisure halls, for example: dance halls, gymnasia, fitness rooms, stages, specialist shops and superstores.

The addition of extra layers does not restrict the range of use and does not change the resistance to concentrated loads. If the flooring elements are laid on top of a concrete slab, the allowable concentrated load rating increases to 2.5 kN for the 2E11 flooring elements and to 3.5 kN for the 2E22 flooring elements. The scope of use extends to field 3 for 2E11 and to field 4 for 2E22.

Fermacell complete acoustic floor-ceiling solutions

  Overall Thickness Fire Rating Airborne Sound Insulation Impact Sound Performance
System Specifications mm mins DnTw+C (L'n,w)
2FCH21
2fch21

Download

Facings 2 layers 10 mm Fermacell Board one side ≥305 60 ≥45 ≤62
Insulation 100 mm mineral wool density 30 kg/m3
Main Floor Min 235 mm x 50 mm solid timber joists at 400 mm centres with 22 mm chipboard overlay
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution MF or resilient bar system set at max 400 mm centres at 90° to joist
2FCH22
2fch22

Robust detail compliant

Download

Facings 2 layers 15 mm Fermacell Board one side ≥320 60* ≥45 ≤62
Insulation 100 mm mineral wool density 30 kg/m3
Main Floor Min 241 mm x 50 mm solid timber I joists at 400 mm centres with 22 mm chipboard overlay
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution MF or resilient bar system set at max 400 mm centres at 90° to joist
2FCS21
2fcs21

Robust detail compliant

Download

Facings 2 layers 12.5 mm Fermacell Board one side ≥305 60 ≥45 ≤62
Insulation 100 mm mineral wool density 40 kg/m3
Main Floor Min 225 mm x 50 mm steel joists at 400 mm centres with 22 mm chipboard overlay. Steel guage as required structurally.
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution MF or resilient bar system set at max 400 mm centres at 90° to joist
2FCM21
2fcm21

Robust detail compliant

Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥45 ≤62
Insulation As required
Main Floor Mass concrete floor 300kg/m2 min
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution 50 mm x 50 mm timber battens at 400 mm centres. Min 75 mm ceiling void
Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥45 ≤62
Insulation As required
Main Floor Mass concrete floor 300kg/m2 min
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution MF ceiling system at 400 mm centres. Min 75 mm ceiling void
2FCM22
2fcm22

Robust detail compliant

Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥50 ≤62
Insulation As required
Main Floor Precast concrete floor 300kg/m2 min + 40mm screed
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution 50 mm x 50 mm timber battens at 400 mm centres. Min 75 mm ceiling void
Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥50 ≤62
Insulation As required
Main Floor Precast concrete floor 300 kg/m2 min + 40 mm screed
Flooring Solution 2E31 or 2E32 Fermacell acoustic flooring element
Ceiling Solution MF ceiling system at 400 mm centres. Min 75 mm ceiling void
2FCM23
2fcm23 Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥45 ≤62
Insulation As required
Main Floor Mass concrete floor 300kg/m2 min
Flooring Solution 2E22 Fermacell flooring element with proprietary hot water floor heating system
Ceiling Solution 50 mm x 50 mm timber battens at 400 mm centres. Min 75 mm ceiling void
Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥45 ≤62
Insulation As required
Main Floor Mass concrete floor 300 kg/m2 min
Flooring Solution 2E22 Fermacell flooring element with proprietary hot water floor heating system
Ceiling Solution MF ceiling system at 400 mm centres. Min 75 mm ceiling void
2FCM24
2fcm24 Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥50 ≤62
Insulation As required
Main Floor Precast concrete floor 300kg/m2 min + 40 mm screed
Flooring Solution 2E22 Fermacell flooring element with proprietary hot water floor heating system
Ceiling Solution 50 mm x 50 mm timber battens at 400 mm centres. Min 75 mm ceiling void
Facings 1 layer 10 mm Fermacell Board one side As required 60 ≥50 ≤62
Insulation As required
Main Floor Precast concrete floor 300 kg/m2min + 40 mm screed
Flooring Solution 2E22 Fermacell flooring element with proprietary hot water floor heating system
Ceiling Solution MF ceiling system at 400 mm centres. Min 75 mm ceiling void